Submersible Bore Pumps.com.au

Range of Franklin
SubMonitor 3 Three Phase Pump Protection

Payment method for your Franklin Electric submersible pump
Home Contact            

Navigation > Home > SubMonitor Three Phase

Search Query
4" Submersible Bore Pumps
4" Pump Wet Ends
4" Pump Motors
4" Pump / Motor Assembly
4" Constant Pressure Systems
4" Subdrive 75 QuickPAK
4" Subdrive 150 QuickPAK
4" Subdrive 300 QuickPAK
6" Submersible Bore Pumps
6" Pump Wet Ends
6" Pump Motors
Controls and Protection
Single 1 Phase Control Box
Single 1 Phase Pumptec
Single 1 Phase Pumptec-Plus
Three 3 Phase SubMonitor
Bore Pump Accessories
Useful Information
What size generator do I need
 

Franklin 0.5 hp bore pumps

Franklin 0.75 hp bore pumps

Franklin 1 hp bore pumps

Franklin 1.5 hp bore pumps

Franklin 2 hp bore pumps

Franklin 3 hp bore pumps

Franklin 5hp bore pumps

Franklin 7.5 hp bore pumps

Franklin 10 hp bore pumps

Franklin 15 hp bore pumps

Franklin 20 hp bore pumps

Franklin 25 hp bore pumps

Franklin 30 hp bore pumps

Franklin 40 hp bore pumps

Franklin 50 hp bore pumps

Franklin 60 hp bore pumps

 

Australia Wide Free Delivery of your Franklin Electric Pump, Motor or Accessories

 

 

 

Franklin Electric pump and motor protection

Franklin has a large range of Controls and Protection for every situation

Franklin Electric Submonitor

SubMonitor

 

SubMonitor, 3-Phase Pump Protection from 2.2 kW to 150 kW

 

 

The SubMonitor is the latest innovation in 3 Phase pump protection from Franklin Electric. Using state-of-the-art technology, the SubMonitor provides the ultimate protection for a pump and motor. There is simply no better way to protect a large 3-phase submersible pump investment than with a SubMonitor. It's the protection device that can sense overheating straight from the motor windings! (for motors equipped with Subtrol sensor)
And it is made by the world leader in submersible motors - Franklin Electric.

Applications

The SubMonitor is designed to protect 3-phase pumps with horsepower ratings between 2.2 and 150 kW. Current, voltage and motor temperature are monitored using three integrated current transformers. A digital display provides current and voltage readings for all three legs and allows the user to set up the SubMonitor quickly and easily.

Features and Benefits

  • Quick setup to monitor a motor, simply enter the Line Frequency (Hz), Line Voltage (volts), and Motor Full Load Amp rating
  • Digital display indicated voltage and current on all three legs at the same time and fault messages are in easily understandable text
  • Monitors
    • Under/Overload
    • Current Unbalance
    • False Start (Chattering)
    • Under/Overvoltage
    • Overheated Motor (Subtrol-Equipped)
    • Phase Reversal
  • For motors with service factor amp ratings between 5 and 350 amps
  • One unit covers the entire range from 190 to 600 Volts
  • No need to make additional turns around the CT or add external CT's
  • Password Protection
  • DIN Rail Mounting
  • Stores fault, setting changes and pump run-time that can be accessed through the display
  • Detachable display unit can be mounted on panel door
  • UL 508 Listed

 

  Description Volts Model No. Price  
SubMonitor Premium 2.2 kW to 150 kW      

SubMonitor Features: Detachable Display Head
4 Text lines
Current/Voltage/faults/settings
PIN access - lockable
DIN rail mounting
Extensive parameter settings to suit site
Data Logging of faults, settings, amps and volts
Data Download to PC via D3 device
       
SubMonitor monitors against: Under/Overload
Current unbalance
False Starts (Chattering)
Ybder/Over voltage
Phase reversal
Overheated Motor (Subtrol equipped 6" 8" encapsulated motors)
       

SubMonitor Premium 2.2 kW to 150 kW 415 586 000 5100 1040
Premium Kit includes: SubMonitor basic plus Lightning arrestor, Display Head Mount Kit, extended warranty period (after registration)

D3
Download data logged in SubMonitor

Data Download Device
Include D3 to PC cable, Data collection reader and CD
Require Windows XP or 2000
1GHz CPU and 256Mb RAM
recommended.
SubMonitor revision 5 or newer

  585 001 1100 535.00

Submonitor Specifications

Model Number

Premium Package:* 586 000 5100

Standard Unit: 586 000 5000
Input Voltage 190 - 600 VAC
Frequency 60/50 Hz
Motor Service Factor Amps 5 to 350 Amps
Maximum Conductor Size Through Sensors Max Diameter: 23mm
Trip Response Motor Under/Overload, Under/Overvoltage, Overheat, Unbalance: 3 seconds
Control Circuit Rating 1.5 Amp AC, up to 600 Volts
Signal Circuit Rating 1 Amp AC, up to 250 volts (Incandescent lamp: 100 watts max)
Wiring Terminals Wire Gauge: 1.0 - 2.5mm2
  Tighten to: 0.5 N-m
Weight (Submonitor) 1.5 Kg
Carton Size (Std. Unit) 19.7 cm x 29.2 cm x 17.1 cm
Shipped Weight 1.5 Kg

* Premium package includes lightning arrestor and 3-year warranty on SubMonitor and Subtrol-equipped motor

Display

Real time display of voltage and current for each let

Easy menu-driven setup and adjustment of monitoring parameters

Display screen for the Franklin Electric SubMonitor

 

Detatchable Display Unit

The detachable display unit displays and stores data it received from the base unit.

Can be mounted on panel door for easy access and display of motor amps and voltage as well as fault messages. Communication cable connects the display to the base unit.

Fault light can be seen from a distance - indicated that a trip has occurred and that a fault message is being displayed.

Turn-and-push adjustment know to access the seup menu, enable or disable monitoring parameters and read fault data history.

Detachable display unit of Franklin Electric SubMonitor

Base Unit

The base unit contains the current sensore and electronics that monitor motor leads that pass through the sensors. It can operate independently of the detachable head.

Can be mounted with 4 screws or with DIN rail.

Dual coloured fault ligh indicated status of the unit

Base Unit of the Franklin Electric SubMonitor - 3 phase Motor Pump Protection

SubMonitor™ pump protection - Much more than an overload sensor

As all water systems professionals know, a submersible installation can be a tough environment for both pump and motor. Sometimes, no matter how professional the installation, things out of an installer's control can severely damage a customer's investment. The answer to such problems is the SubMonitor pump protection system, which offers state-of-the-art protection for Franklin 3- phase installations all the way from 5 through 200 Hp. The SubMonitor system keeps track of voltage and current, as well as motor temperature in motors equipped with Subtrol heat sensors. Introduced in 2004, SubMonitor protection will shut down a motor in the event of a variety of fault conditions including high voltage, low voltage, overload, underload, false start, current unbalance, overheating, phase loss and phase reversal. The unit is easy to set and read. And, one model covers all ratings - without rating inserts.

SubMonitor protection is available in three options: Standard, Premium and Panel-Mounted. SubMonitor Standard includes the SubMonitor base unit and display head only, while SubMonitor Premium adds a surge arrestor and is eligible for an extended warranty when installed with a new motor. The Panel-Mounted SubMonitor system is installed in a Franklin 3-phase control panel and also provides the extended warranty.

SubMonitor Setup.
For all of the protection described above, SubMonitor set-up is easy and accomplished with a simple display and turn-and-push knob. When installing the unit, simply select the motor frequency (50 or 60 Hz), voltage and service factor amps (from the motor nameplate or AIM Manual). At that point, the unit is ready to run using factory-default settings. To accommodate individual installations, the user can easily adjust the factory defaults. See the chart for a list of programmable options.

SubMonitor mounted on control box

SubMonitor Operation.
Once the SubMonitor system is operational, the readout on the display head shows voltage and current on each leg, as well as pumping status. The fault light can be seen from a distance, indicating that a trip has occurred and that a fault message is being displayed. The SubMonitor memory can recall a history of the past 500-plus events.
When set to "Detailed Logging" mode, "events" mayinclude normal starts and stops, fault trips and any changes made in parameters. The event history can be reviewed at any time via the Data Logging option on the SubMonitor menu. A handheld unit is now available that allows you to download the event history to a computer.

 
Get a Quote  
   

Please Choose Carefully!

When Purchasing a product from this website, please be sure that you have made the correct choice. You accept the risks and responsibility of your purchase and that you have made the correct product choice - The onus is on you. I have provided information on products as well as contact details to help you choose the Franklin product that will suit your needs.