Submersible Bore Pumps.com.au

Range of Franklin
Control Boxes 1 Single Phase

Payment method for your Franklin Electric submersible pump
Home Contact            

Navigation > Home > Single Phase Control Boxes

Search Query
4" Submersible Bore Pumps
4" Pump Wet Ends
4" Pump Motors
4" Pump / Motor Assembly
4" Constant Pressure Systems
4" Subdrive 75 QuickPAK
4" Subdrive 150 QuickPAK
4" Subdrive 300 QuickPAK
6" Submersible Bore Pumps
6" Pump Wet Ends
6" Pump Motors
Controls and Protection
Single 1 Phase Control Box
Single 1 Phase Pumptec
Single 1 Phase Pumptec-Plus
Three 3 Phase SubMonitor
Bore Pump Accessories
Useful Information
What size generator do I need
 

Franklin 0.5 hp bore pumps

Franklin 0.75 hp bore pumps

Franklin 1 hp bore pumps

Franklin 1.5 hp bore pumps

Franklin 2 hp bore pumps

Franklin 3 hp bore pumps

Franklin 5hp bore pumps

Franklin 7.5 hp bore pumps

Franklin 10 hp bore pumps

Franklin 15 hp bore pumps

Franklin 20 hp bore pumps

Franklin 25 hp bore pumps

Franklin 30 hp bore pumps

Franklin 40 hp bore pumps

Franklin 50 hp bore pumps

Franklin 60 hp bore pumps

 

Australia Wide Free Delivery of your Franklin Electric Pump, Motor or Accessories

 

 

Franklin Electric's range of Single Phase Control Boxes

Range of Single Phase Control Boxes

Franklin Electric QD Single Phase Control Box

QD Control Box

Franklin Motors Single 1 Phase Control Box

 

 

 

Basic Features - All Boxes

  • Suitable for Outdoor Mounting
  • Capacitor Start / Capacitor Run Design (Except QD Boxes)

Applications

  • QD - These control boxes are designed for use with Franklin 3-wire single-phase submersible motors through 0.75 kW
  • STANDARD - These control boxes are designed for use with Franklin 3-wire single phase submersible motors from 1.1 to 3.7 kW
    Recommended for water systems that use standard / heavy-duty pressure switches, level switches or other pilot devices.

Features

  • Heavy Duty Box-Type Terminals
  • External Access to Overload Resets
  • Multi-size Knockouts
  • User friendly Connection Diagrams
  • Easy access to Grounding Lugs

 

Box Type HZ HP Range kW Range Enclosure Terminals Max wire MAG CONTACTOR
Quick Disconnect (QD) 50 1/3 - 1 0.25 - 0.75 NEMA 3R, IP23 5 4 mm No
Standard (S) 50 1.5 to 5 1.1 - 3.7 NEMA 3R, IP23 6 35 mm No

 


Enclosure - QD Boxes

  • Knockout Bottoms: Two 7/8" knockouts and one 1 1/8" knockout.
    Side: One 7/8" knockout and one 1 1/8" knockout on each side
  • Terminal Block: 5 terminals provided for wiring
SHIPPING WEIGHT Motor Carton Size Enc Size
HP kW KG
1 0.75 1.8 140 x 82 x 228 QD
Franklin's Single 1 Phase control box Franklin Electric Single Phase Control Box Dimensions

Enclosure - Standard Boxes

  • Knockout Bottoms: Two 1.32 " diameter holes for 1-inch conduit connection
  • Terminal Block: 6 terminals provided for wiring
Franklin Single Phase Control Box to suit 0.75kw 1.1kw 1.5kw 2.2kw and 3.7kw Franklin Single Phase Motors

Standard Control Boxes

 

Dimensions for Franklin Standard Control Box

Standard Dimensions

SHIPPING WEIGHT Motor Carton Size Enc Size
HP kW KG
1.5 1.1 3.2 206 x 159 x 286 A
2 1.5 3.2 206 x 159 x 286 A
3 2.2 3.2 206 x 159 x 286 A
5 3.7 3.6 206 x 159 x 145 B

Control Box Prices

Control Box Description Volts   Model No. Price  

0.75 kW

230

CS-IR

280 373 0119

124.00

1.1 KW

230

CS-CR

282 360 8119

168.00

1.5 KW

230

CS-CR

282 361 8119

270.00

1.5 KW

230

PSC

284 380 4705

123.00

2.2 KW

230

CS-CR

282 362 8110

336.00

3.7 KW

230

CS-CR

282 363 9010

485.00

IMPORTANT:
A matching kW rating Franklin Electric Control Box must be used with each Single Phase 230V motor or warranty is VOID.

Control Box Parts List

Control Box kW size Description Model No. Price  

1.5 kW PSC

CAPACITOR START/RUN 50mfd 440V
OVERLOAD, Built into 1.5kW PSC motor
155 379 103

23.10

         

0.75 kW CSIR

CAPACITOR/OVERLOAD 86-103mfd 220V 305 218 918

27.00

         

1.1 kW CSCR

CAPACITOR RUN 10mfd 370V 305 204 902

26.90

1.1 kW CSCR

CAPACITOR START 105-126mfd 220V 305 207 913

32.60

1.1 kW CSCR

OVERLOAD 305 215 914

12.25

         

1.5 Kw CSCR

CAPACITOR RUN 20mfd 370V 305 204 903

32.25

1.5 Kw CSCR *

*CAPACITOR START 189-227mfd 220V 305 208 915

53.40

1.5 Kw CSCR *

*OVERLOAD START 305 215 902

14.05

1.5 Kw CSCR

OVERLOAD START 305 215 906

13.00

         

2.2Kw CSCR


CAPACITOR RUN 35mfd 370V 305 203 902

43.35

2.2Kw CSCR


CAPACITOR START 270-324mfd 330V 305 208 919

90.15

2.2Kw CSCR

OVERLOAD RUN 305 214 907

34.15

2.2Kw CSCR

OVERLOAD START 305 215 907

12.25

         

3.7 kW CSCR

CAPACITOR RUN 30mfd 370V 305 203 901

39.20

3.7 kW CSCR

CAPACITOR RUN 45mfd 370V 305 203 909

49.45

3.7 kW CSCR *

*CAPACITOR START 189-227mfd 220V 305 208 915

53.40

3.7 kW CSCR

OVERLOAD RUN 305 214 902

31.30


3.7 kW CSCR *

*OVERLOAD START 305 215 902

14.05

         
  * Used in more than one model CB      
         

All CB

Relay Kit 50Hz 305 213 912

56.30

 
Get a Quote  
   

Please Choose Carefully!

When Purchasing a product from this website, please be sure that you have made the correct choice. You accept the risks and responsibility of your purchase and that you have made the correct product choice - The onus is on you. I have provided information on products as well as contact details to help you choose the Franklin product that will suit your needs.